Power Station Ranking

Home › Extra Large (3,000 Wh and up) › EcoFlow Delta Pro 3

EcoFlow Delta Pro 3

EcoFlow Delta Pro 3

#7 of 13 in extra large · #39 of 56 overall · all EcoFlow models
3.2

4kWh unit with native 120/240V output, 2600W solar input and 10ms UPS.

4,096 Whcapacity
4,000 Wcontinuous output
LiFePO44,000 cycles
113.5 lbweight
$2,999street price, being verified
Runs a 500 W load about 7.0 h$732 per kWh of capacityFull AC recharge in about 2.6 hUPS switchover 10 msExpands to 12,000 Wh120/240 V output

Ratings

Includes independent measurements from ComputerBase, OutdoorGearLab, The Solar Lab.

Value25% of the score
1.0
Power output15% of the score
2.0
Battery longevity15% of the score
5.0
Recharge speed15% of the score
1.0
Portability10% of the score
2.5
Features10% of the score
5.0
Tested capacity10% of the score
5.0

Each rating places this unit among the others on a 0.5–5 scale, within its size class for the measures that scale with size and across the whole catalog for the rest. Weighted together they give the overall 3.2. Formula and weights.

Specifications

Capacity
4,096 Wh
Max expanded
12,000 Wh
AC output
4,000 W continuous
Surge
8,000 W
Chemistry
LiFePO4
Cycle rating
4,000
Weight
113.5 lb
AC recharge
1,800 W
Solar input
2,600 W
UPS switchover
10 ms
AC outlets
5
USB-C PD max
140 W
240V output
Yes
App
Yes
Price per kWh
$732
Released
2024

Independent measurements

MetricValueSource
Usable capacity, % of rated
Light-bar load bank through AC outlets; 3790 Wh delivered of 4096 rated (article rounds to 93%)
92.5 %OutdoorGearLab
2026-01
AC recharge time
Table lists 3.2 h from AC at 1293 Wh/h average; text says about 3 h; peak input ~1600W
192 minOutdoorGearLab
2026-01
Runtime efficiency
Sustained 3650W load for 60 min (near max rating)
89 %The Solar Lab
AC recharge time
2 h 54 min via 120V AC port; display stalled at 2 min remaining for a while; start/end SoC not stated
174 minThe Solar Lab
Sustained output
3650W held 60 min; ~5100W overload held nearly 1 min before shutdown
3650 WThe Solar Lab
Usable capacity, % of rated
500W constant AC load; 3911 Wh delivered of 4096 rated (230V unit)
95.5 %ComputerBase
2024-10
Usable capacity, % of rated
2000W constant AC load; 3999 Wh delivered of 4096 rated; 4812 Wh from wall to refill at 1000W charge setting
97.6 %ComputerBase
2024-10
Usable capacity at a trickle load (shown, not scored)
120W constant AC load; 3311 Wh delivered of 4096 rated
80.8 %ComputerBase
2024-10
AC recharge time
0-100% at the 2900W charge setting on a 230V outlet; ~2700-2800W input until ~75%
118 minComputerBase
2024-10
Noise
Peak at 30 cm front under a 3700W load (same peak while charging at 2900W); under ~1100W stayed below the 30 dB meter floor; 52.5 when charging and discharging simultaneously
42.8 dBAComputerBase
2024-10
Sustained output
3700W load used for noise test; 2000W constant load run through a full discharge
3700 WComputerBase
2024-10

How it compares with its neighbors

#ModelWhAC WChem.CycleslbAC in WSolar W$/kWhScore
4Anker SOLIX F30003,0723,600LiFePO43,00085.52,0001,6006513.4
5Anker SOLIX F3800 Plus3,8406,000LiFePO44,000132.03,2003,0009113.3
6Anker SOLIX F38003,8406,000LiFePO43,000132.01,8002,4007813.2
7EcoFlow Delta Pro 34,0964,000LiFePO44,000113.51,8002,6007323.2
8Bluetti AC300 + B3003,0723,000LiFePO43,500127.03,0002,4007163.1
9EcoFlow Delta Pro Ultra6,1447,200LiFePO43,500180.03,8005,6008143.0
10EcoFlow Delta Pro3,6003,600LiFePO43,50099.01,8001,6006942.9